227956-5ELECTRIC SALAMANDERE91E91BI N S T A L L A T I O N A N D O P E R A T I O N M A N U A LFor use in GB & IE
8OperationOperation Guide1. The Blue Seal Salamanders have been designed to provide simplicity of operation and 100% safetyprotection.2. Improper oper
9Operating the ControlsTurning on the Elements to the LOW Position1. Check that the electrical supply is turned on. The power indicator neon will illu
10Cooking Recommendations1. This equipment has been designed to give a good evenness of heat across the rack area, sotoasting, cheese melting and gril
11General To achieve the best results, cleaning must be thorough, and all controls and mechanical partschecked and adjusted periodically by a compet
12This section provides an easy reference guide to the more common problems that may occur during theoperation of your equipment. The fault finding gu
13Circuit DiagramCircuit DiagramL1NEOUTER1100W1900W1100W1900WOUTER0OFF 750W1 21900W 3000W3CONTROL SWITCH SETTINGS432P2P1432P2P1
14Replacement Parts ListWhen ordering spare parts, please quote the part number and the description as listed below. If the partrequired is not listed
15
The reproduction or copying of any part of this manual by any means whatsoever is strictly forbidden unless authorized previously inwriting by the man
E91 ELECTRIC SALAMANDER (Branding Plate Optional)E91B ELECTRIC SALAMANDER (With Branding Plate)Introduction ...
2IntroductionWe are confident that you will be delighted with your BLUE SEAL Electric Salamander, and it will become amost valued appliance in your co
3Model Numbers Covered in this SpecificationE91 Electric Salamander (Branding Plate Optional)E91B Electric Salamander with Branding Plate.GeneralA com
4Dimensions:SpecificationsInternal DimensionsWidth 685 mm.Height 230 mm (at front).Depth 330 mm.Cooking AreaRack 610mm x 310mm.Branding Plate (Accesso
5Installation RequirementsNOTE: It is most important that this salamander is installed correctly and that operation iscorrect before use. Installation
6ClearancesThis unit must be installed on a non-combustible wall or tailored stand with the following clearances:-NOTE: Top clearances can be reduced
7Electrical ConnectionWhen connecting a Blue Seal electric appliance to the main supply, ensure that the following iscarried out:- An isolating swit