234060-3 GAS SALAMANDER G91 G91B INSTALLATION AND OPERATION MANUAL For use in GB & IE
8 Wall Mounting (to Non-Combustible Wall Only) 1. Fix the wall mounting bracket to the wall with six screws, in such a position that the top of the
9 Gas Connection NOTE: ALL GAS FITTING MUST ONLY BE CARRIED OUT BY A QUALIFIED SERVICE PERSON. 1. Blue Seal Salamanders do not require an electrica
10 7. Check that the gas operating pressure is as shown in ‘Specifications’ section. NOTE: The operating pressure to be measured at the manifold te
11 Operation Guide 1. Blue Seal Salamanders have been designed to provide simplicity of operation and 100% safety protection. 2. Improper operation
12 Lighting the Main Burners 1. Check that the gas supply is turned 'On'. 2. Depress the gas control knob and rotate anti-clockwise to the
13 General To achieve the best results, cleaning must be thorough, and all controls and mechanical parts checked and adjusted periodically by a co
14 Periodic Maintenance NOTE: All maintenance operations should only be carried out by a qualified service person. To achieve the best results clea
15 This section provides an easy reference guide to the more common problems that may occur during the operation of your equipment. The fault finding
16 Conversion Procedure NOTE: These conversions should only be carried out by qualified persons. All connections must be checked for leaks before
17 Gas Conversion Gas Regulator NOTE: The regulator supplied is convertible between Natural Gas and LPG, but it’s outlet pressure is fixed ex-factor
The reproduction or copying of any part of this manual by any means whatsoever is strictly forbidden unless authorized previously in writing by the ma
18 Gas Conversion Commissioning Before leaving the converted installation; 1. Check all gas connections for leakages using soapy water or other gas d
19 Replacement Parts List When ordering spare parts, please quote the part number and the description as listed below. If the part required is not li
G91 GAS SALAMANDER (Branding Plate Optional) G91B GAS SALAMANDER (With Branding Plate) Introduction ...
2 We are confident that you will be delighted with your Blue Seal Gas Salamander, and it will become a most valued appliance in your commercial kitch
3 Model Numbers Covered in this Specification G91 Gas Salamander. G91B Gas Salamander. General A commercial heavy duty, wall mounted gas fired inf
4 Specifications Gas Supply Requirements NOTE: * The burner operating pressure is to be measured at the manifold test point with both burners opera
5 Dimensions: Dimensions Internal Dimensions Width 685 mm. Height 230 mm (at front). Depth 330 mm. Cooking Area Rack 610 mm x 310 mm. Branding
6 Installation Requirements NOTE: It is most important that this salamander is installed correctly and that operation is correct before use. Instal
7 7. Components having adjustments protected (e.g. paint sealed) by the manufacturer are only to be adjusted by an authorised service agent. They are