Installation
6
Blue Seal Evolution Series GT45 / GT46 / GT60 © Moffat Ltd, January 2007
Revision 1/
4. All air for burner combustion is supplied from underneath the appliance. The legs must always be
fitted and no obstructions placed on the underside or around the base of the appliance, as
obstructions will cause incorrect operation and/or failure of the appliance.
5. Components having adjustments protected (e.g. paint sealed) by manufacturer are only allowed to
be adjusted by an authorised service agent. They are not to be adjusted by the installation person.
NOTE: Do not obstruct or block the appliances flue. Never directly connect a ventilation system to
the appliance flue outlet.
Clearances
NOTE:
Only non-combustible materials can be used in close proximity to this appliance.
In order to facilitate easy operation, drainage and servicing of the appliance, a
minimum of 600mm clearance should be maintained at the front of the appliance.
Any gas burning appliance requires adequate clearance and ventilation for optimum and trouble-free
operation. The following minimum installation clearances are to be adhered to:
Assembly
This model is delivered completely assembled. Ensure that the legs are securely attached.
NOTE:
This appliance is fitted with adjustable feet to enable the appliance to be positioned
securely and level. This should be carried out on completion of the gas connection.
Refer to the “Gas Connection” section below.
Optional Accessories (Refer to Replacement Parts List)
Plinth Kit. For installation details, refer to the instructions supplied with each kit.
Gas Connection
NOTE: ALL GAS FITTING MUST ONLY BE CARRIED OUT BY A QUALIFIED SERVICE PERSON.
1. Blue Seal Fryers do not require an electrical connection, they function totally on the gas supply only.
2. It is essential that the gas supply is correct for the appliance to be installed and that adequate
supply pressure and volume are available. The following checks should therefore be made before
installation:-
a. The Gas Type the appliance has been supplied for is shown on
coloured stickers located above the gas entry point and next to
the rating plate. Check that this is correct for the gas supply
the appliance is being installed for. The gas conversion
procedure is detailed in this manual.
b. Supply Pressure required for this appliance is shown in the
“Specifications” section of this manual. Check the gas supply to
ensure that adequate supply pressure exists.
c. Input Rate of this appliance is also stated on the Rating Plate
fitted to the inside of the access door and in the
“Specifications” section of this manual. The input rate should
be checked against the available gas supply line capacity.
Particular note should be taken if the appliance is being
added to an existing installation.
Rating Plate
Location
Combustible Surface Non Combustible Surface
Left/Right hand side 50 mm 0 mm
Rear 50 mm 0 mm